{"id":7991,"date":"2020-03-19T17:36:21","date_gmt":"2020-03-19T17:36:21","guid":{"rendered":"https:\/\/roofingcanada.com\/docs\/manuel-de-reference-sur-les-couvertures-au-canada-chapitre-1-securite\/1-3-propane\/1-3-1-inflammabilite\/"},"modified":"2020-03-19T18:17:40","modified_gmt":"2020-03-19T18:17:40","slug":"1-3-1-inflammabilite","status":"publish","type":"docs","link":"https:\/\/roofingcanada.com\/fr\/docs\/manuel-de-reference-sur-les-couvertures-au-canada\/chapitre-1-securite\/1-3-propane\/1-3-1-inflammabilite\/","title":{"rendered":"1.3.1 Inflammabilit\u00e9"},"content":{"rendered":"<p>Le gaz propane est extr\u00eamement inflammable et tout ce qui est n\u00e9cessaire pour qu\u2019il y ait combustion, c\u2019est une quantit\u00e9 suffisante de gaz propane m\u00e9lang\u00e9 avec de l\u2019oxyg\u00e8ne (de l\u2019air) et une source d\u2019inflammation. La plage d\u2019inflammabilit\u00e9 comprend les quantit\u00e9s de gaz propane qui doivent se trouver dans un m\u00e9lange propane-air pour le faire br\u00fbler. La plage pour le gaz propane est de 2,4 \u00e0 9,5% de tout le m\u00e9lange propane-oxyg\u00e8ne. Cela signifie que tout pourcentage de gaz propane dans un m\u00e9lange propane-air entre 2,4% et 9,5% sera suffisant pour que le gaz propane s\u2019enflamme. Si un m\u00e9lange contient 2% de gaz propane et 98 % d\u2019oxyg\u00e8ne, il n\u2019y aura pas de combustion. Si un m\u00e9lange contient 10% de gaz propane et 90% d\u2019oxyg\u00e8ne, il ne se produira pas de combustion. <strong>Toutefois, un mauvais m\u00e9lange air-gaz peut produire du <\/strong><a href=\"http:\/\/www.propane101.com\/carbonmonoxideandpropane.htm\"><strong>monoxyde de carbone (CO)<\/strong><\/a><strong> qui est un produit mortel de la combustion incompl\u00e8te<\/strong>.<\/p>\n","protected":false},"featured_media":0,"parent":7990,"menu_order":0,"comment_status":"open","ping_status":"closed","template":"","doc_tag":[],"class_list":["post-7991","docs","type-docs","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>1.3.1 Inflammabilit\u00e9 - Canadian Roofing Contractors Association<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/roofingcanada.com\/fr\/docs\/manuel-de-reference-sur-les-couvertures-au-canada\/chapitre-1-securite\/1-3-propane\/1-3-1-inflammabilite\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"1.3.1 Inflammabilit\u00e9 - Canadian Roofing Contractors Association\" \/>\n<meta property=\"og:description\" content=\"Le gaz propane est extr\u00eamement inflammable et tout ce qui est n\u00e9cessaire pour qu\u2019il y ait combustion, c\u2019est une quantit\u00e9 suffisante de gaz propane m\u00e9lang\u00e9 avec de l\u2019oxyg\u00e8ne (de l\u2019air) et une source d\u2019inflammation. La plage d\u2019inflammabilit\u00e9 comprend les quantit\u00e9s de gaz propane qui doivent se trouver dans un m\u00e9lange propane-air pour le faire br\u00fbler.... En savoir plus \u00bb\" \/>\n<meta property=\"og:url\" content=\"https:\/\/roofingcanada.com\/fr\/docs\/manuel-de-reference-sur-les-couvertures-au-canada\/chapitre-1-securite\/1-3-propane\/1-3-1-inflammabilite\/\" \/>\n<meta property=\"og:site_name\" content=\"Canadian Roofing Contractors Association\" \/>\n<meta property=\"article:modified_time\" content=\"2020-03-19T18:17:40+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/roofingcanada.com\\\/fr\\\/docs\\\/manuel-de-reference-sur-les-couvertures-au-canada\\\/chapitre-1-securite\\\/1-3-propane\\\/1-3-1-inflammabilite\\\/\",\"url\":\"https:\\\/\\\/roofingcanada.com\\\/fr\\\/docs\\\/manuel-de-reference-sur-les-couvertures-au-canada\\\/chapitre-1-securite\\\/1-3-propane\\\/1-3-1-inflammabilite\\\/\",\"name\":\"1.3.1 Inflammabilit\u00e9 - Canadian Roofing Contractors Association\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/roofingcanada.com\\\/#website\"},\"datePublished\":\"2020-03-19T17:36:21+00:00\",\"dateModified\":\"2020-03-19T18:17:40+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/roofingcanada.com\\\/fr\\\/docs\\\/manuel-de-reference-sur-les-couvertures-au-canada\\\/chapitre-1-securite\\\/1-3-propane\\\/1-3-1-inflammabilite\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/roofingcanada.com\\\/fr\\\/docs\\\/manuel-de-reference-sur-les-couvertures-au-canada\\\/chapitre-1-securite\\\/1-3-propane\\\/1-3-1-inflammabilite\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/roofingcanada.com\\\/fr\\\/docs\\\/manuel-de-reference-sur-les-couvertures-au-canada\\\/chapitre-1-securite\\\/1-3-propane\\\/1-3-1-inflammabilite\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Manuel de r\u00e9f\u00e9rence sur les couvertures au Canada\",\"item\":\"https:\\\/\\\/roofingcanada.com\\\/fr\\\/docs\\\/manuel-de-reference-sur-les-couvertures-au-canada\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Chapitre 1 : S\u00e9curit\u00e9\",\"item\":\"https:\\\/\\\/roofingcanada.com\\\/fr\\\/docs\\\/manuel-de-reference-sur-les-couvertures-au-canada\\\/chapitre-1-securite\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"1.3 Propane\",\"item\":\"https:\\\/\\\/roofingcanada.com\\\/fr\\\/docs\\\/manuel-de-reference-sur-les-couvertures-au-canada\\\/chapitre-1-securite\\\/1-3-propane\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"1.3.1 Inflammabilit\u00e9\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/roofingcanada.com\\\/#website\",\"url\":\"https:\\\/\\\/roofingcanada.com\\\/\",\"name\":\"Canadian Roofing Contractors Association\",\"description\":\"Sous un seul toit\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/roofingcanada.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"1.3.1 Inflammabilit\u00e9 - Canadian Roofing Contractors Association","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/roofingcanada.com\/fr\/docs\/manuel-de-reference-sur-les-couvertures-au-canada\/chapitre-1-securite\/1-3-propane\/1-3-1-inflammabilite\/","og_locale":"fr_FR","og_type":"article","og_title":"1.3.1 Inflammabilit\u00e9 - Canadian Roofing Contractors Association","og_description":"Le gaz propane est extr\u00eamement inflammable et tout ce qui est n\u00e9cessaire pour qu\u2019il y ait combustion, c\u2019est une quantit\u00e9 suffisante de gaz propane m\u00e9lang\u00e9 avec de l\u2019oxyg\u00e8ne (de l\u2019air) et une source d\u2019inflammation. La plage d\u2019inflammabilit\u00e9 comprend les quantit\u00e9s de gaz propane qui doivent se trouver dans un m\u00e9lange propane-air pour le faire br\u00fbler.... En savoir plus \u00bb","og_url":"https:\/\/roofingcanada.com\/fr\/docs\/manuel-de-reference-sur-les-couvertures-au-canada\/chapitre-1-securite\/1-3-propane\/1-3-1-inflammabilite\/","og_site_name":"Canadian Roofing Contractors Association","article_modified_time":"2020-03-19T18:17:40+00:00","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/roofingcanada.com\/fr\/docs\/manuel-de-reference-sur-les-couvertures-au-canada\/chapitre-1-securite\/1-3-propane\/1-3-1-inflammabilite\/","url":"https:\/\/roofingcanada.com\/fr\/docs\/manuel-de-reference-sur-les-couvertures-au-canada\/chapitre-1-securite\/1-3-propane\/1-3-1-inflammabilite\/","name":"1.3.1 Inflammabilit\u00e9 - Canadian Roofing Contractors Association","isPartOf":{"@id":"https:\/\/roofingcanada.com\/#website"},"datePublished":"2020-03-19T17:36:21+00:00","dateModified":"2020-03-19T18:17:40+00:00","breadcrumb":{"@id":"https:\/\/roofingcanada.com\/fr\/docs\/manuel-de-reference-sur-les-couvertures-au-canada\/chapitre-1-securite\/1-3-propane\/1-3-1-inflammabilite\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/roofingcanada.com\/fr\/docs\/manuel-de-reference-sur-les-couvertures-au-canada\/chapitre-1-securite\/1-3-propane\/1-3-1-inflammabilite\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/roofingcanada.com\/fr\/docs\/manuel-de-reference-sur-les-couvertures-au-canada\/chapitre-1-securite\/1-3-propane\/1-3-1-inflammabilite\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Manuel de r\u00e9f\u00e9rence sur les couvertures au Canada","item":"https:\/\/roofingcanada.com\/fr\/docs\/manuel-de-reference-sur-les-couvertures-au-canada\/"},{"@type":"ListItem","position":2,"name":"Chapitre 1 : S\u00e9curit\u00e9","item":"https:\/\/roofingcanada.com\/fr\/docs\/manuel-de-reference-sur-les-couvertures-au-canada\/chapitre-1-securite\/"},{"@type":"ListItem","position":3,"name":"1.3 Propane","item":"https:\/\/roofingcanada.com\/fr\/docs\/manuel-de-reference-sur-les-couvertures-au-canada\/chapitre-1-securite\/1-3-propane\/"},{"@type":"ListItem","position":4,"name":"1.3.1 Inflammabilit\u00e9"}]},{"@type":"WebSite","@id":"https:\/\/roofingcanada.com\/#website","url":"https:\/\/roofingcanada.com\/","name":"Canadian Roofing Contractors Association","description":"Sous un seul toit","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/roofingcanada.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"}]}},"comment_count":0,"_links":{"self":[{"href":"https:\/\/roofingcanada.com\/fr\/wp-json\/wp\/v2\/docs\/7991","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/roofingcanada.com\/fr\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/roofingcanada.com\/fr\/wp-json\/wp\/v2\/types\/docs"}],"replies":[{"embeddable":true,"href":"https:\/\/roofingcanada.com\/fr\/wp-json\/wp\/v2\/comments?post=7991"}],"version-history":[{"count":2,"href":"https:\/\/roofingcanada.com\/fr\/wp-json\/wp\/v2\/docs\/7991\/revisions"}],"predecessor-version":[{"id":8061,"href":"https:\/\/roofingcanada.com\/fr\/wp-json\/wp\/v2\/docs\/7991\/revisions\/8061"}],"up":[{"embeddable":true,"href":"https:\/\/roofingcanada.com\/fr\/wp-json\/wp\/v2\/docs\/7990"}],"next":[{"title":"1.3.2 Bouteilles\/R\u00e9servoirs","link":"https:\/\/roofingcanada.com\/fr\/docs\/manuel-de-reference-sur-les-couvertures-au-canada\/chapitre-1-securite\/1-3-propane\/1-3-2-bouteilles-reservoirs\/","href":"https:\/\/roofingcanada.com\/fr\/wp-json\/wp\/v2\/docs\/8062"}],"wp:attachment":[{"href":"https:\/\/roofingcanada.com\/fr\/wp-json\/wp\/v2\/media?parent=7991"}],"wp:term":[{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/roofingcanada.com\/fr\/wp-json\/wp\/v2\/doc_tag?post=7991"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}